chemical engineering process control and instrumentation Mcqs
3. Which of the following thermocouples has the least temperature measurement range ?
comments icon0
A. Copper-constantan

B. Chromel-alumel

C. Iron-constantan

D. Platinum-platinum/rhodium

6. Thermistors are made of__________________?
comments icon0

A. Nickel-chromium alloys

B. Iron-copper alloys

C. Ultra pure metals

D. Metal oxides
7. A system with a double pole at the origin is unstable since the corresponding term in the time domain________________?
comments icon0
A. Grows linearly with time

B. Decays linearly with time

C. Is a constant

D. Grows exponentially with time

8. Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by__________________?
comments icon0
A. All A , B & C.

B. Making the volume of thermometer bulb as large as conveniently possible

C. Reducing the volume of the receiving element to a minimum

D. Reducing the volume of the capillary to a minimum

10. A barometer measures the _____________ pressure?
comments icon0
A. Absolute

B. Gauge

C. Absolute as well as gauge

D. dynamic

12. Composition of alloys can be determined by _________________?
comments icon0
A. Polarograph

B. Refractometer

C. None of these

D. Chromatograph

14. Normal mercury thermometer can be used to measure a temperature of about 300C. However, its maximum temperature measurement range can be increased upto about 500C by__________________?
comments icon0
A. Filling nitrogen under pressure in the stem

B. Accounting for the tube expansion

C. Using steel tube in place of glass tube

D. Increasing the diameter of the tube

15. A sinusoidal variation in the input passing through a linear first order system _________________?
comments icon0
A. Gets attenuated (magnitude decreases)

B. Becomes more oscillatory (frequency increases)

C. Gets amplified (magnitude increases)

D. Becomes less oscillatory (frequency decreases)

16. Working principle of mercury in glass thermometer is based on the ______________ of mercury with increase in temperature?
comments icon0
A. Volumetric expansion

B. Increase of pressure

C. Differential linear expansion

D. Increase of thermal conductivity

17. A bolometer is __________________?
comments icon0

A. Used for the measurement of thermal radiation

B. An element which senses optical input and delivers thermal output

C. Both A. & B.

D. Neither A. nor B.

18. Concentration of sugar solution can be determined by the__________________?
comments icon0

A. Oscillometry

B. Flame photometry

C. Emission spectroscopy

D. Polarimetry
20. A pyranometer is an instrument used for measuring the___________________?
comments icon0

A. Beam radiation

B. Bright sunshine period

C. None of these

D. Global radiation
25. Gas chromatography is used for the measurement of ________________?
comments icon0

A. Pressure

B. Concentration

C. Temperature

D. Flow rate

28. Which of the following does not figure in the list of seven substances selected for international temperature scale ?
comments icon0

A. Antimony and silver (F.P)

B. Oxygen and sulphur (B.P)

C. Ice (F.P) and steam (B.P)

D. Zinc (B.P) and mercury (F.P)
31. The transfer function of a first order system is______________?
comments icon0

A. 1/Ts

B. s/(Ts + 1)

C. None of these

D. 1/(Ts + 1)
33. Mcleod gauge is used to measure the __________________?
comments icon0

A. Point velocity

B. Pressure

C. Vacuum

D. Flow rate

34. Measurement of pressure in ammonia reactor is done by __________________?
comments icon0

A. Pirani gauge

B. U-tube manometer

C. Bourdon gauge

D. Inclined tube manometer

35. The Laplace transform of exp(at), where a > 0, is defined only for the Laplace parameter, s > a since______________?
comments icon0
A. The Laplace transform of integral of exp(at) has finite values only for s > a

B. The function exp(at) is piece-wise continuous only for s > a

C. The Laplace transform integral of exp(at) has initial values only for s > a

D. The function is exponential

37. Dilatometer is used to measure __________________?
comments icon0

A. Deflection

B. Contraction/expansion due to changes in temperature

C. Stress

D. Strain

42. Temperature of _____________ cannot be measured by an optical or radiation pyrometer?
comments icon0

A. Rotary limestone calcination kiln

B. Combustion space in boilers

C. Molten slag flowing out of blast furnace

D. Hot blast (air) from stoves
44. Radiation thermometer cannot measure the temperature ___________________?
comments icon0
A. Of liquid oxygen

B. Inside a pressure vessel

C. Of an object without coming in contact with it

D. Of moving objects at high temperature

47. Liquid levels in autoclaves are measured by ________________?
comments icon0

A. None of these

B. Differential float type manometer

C. Simple float

D. Glass gauge

48. When the damping co-efficient (?) is unity, the system is __________________?
comments icon0

A. Underdamped

B. Critically damped

C. Overdamped

D. Highly fluctuating

49. Optical activity of a solution can be determined using a ___________________?
comments icon0

A. Dilatometer

B. Polarograph

C. Polarimeter

D. Refractometer