chemical engineering process control and instrumentation Mcqs
51. Thermal conductivity cell is the primary element of a/an _____________ analyser?
comments icon0

A. Oxygen

B. Carbon dioxide

C. Carbon monoxide

D. Sulphur dioxide

54. Measurement of sub-zero Celsius temperature in industry is done most commonly by __________________?
comments icon0

A. Thermocouples

B. Gas thermometers

C. Resistance thermometers

D. Bi-metallic thermometers

56. If response of a control system is to be free of offset and oscillation, the most suitable controller is_________________?
comments icon0

A. Proportional-integral (PI) controller

B. Proportional controller

C. Proportional-derivative (PD) controller

D. Proportional integral-derivative (PID) controller
57. Flow rate measurement of hostile acids and alkalis can be most suitably done by a/an ________________?
comments icon0

A. Hot wire anemometer

B. Venturimeter

C. Orificemeter

D. Magnetic flow meter
61. The unit step response of the transfer function (2s 1)/[(3s + 1) (4s + 1)] reaches its final steady state asymptotically after _____________?
comments icon0

A. A monotonic decrease

B. A monotonic increase

C. Initially increasing and then decreasing

D. Increasing decreasing and then increasing

62. Bourdon tube is never made of________________?
comments icon0

A. Monel metal

B. Cast iron

C. Stainless steel

D. Phosphor bronze

63. Conversion formula for converting amplitude ratio (AR) into decibels is ________________?
comments icon0

A. Decibel = 20 log10 (AR)0.5

B. Decibel = 20 log10 (AR)

C. Decibel = 20 loge (AR)

D. Decibel = 20 loge (AR)0.5

64. Routh test_________________?
comments icon0

A. Criterion is not applicable to systems with polynomial characteristic equation

B. Criterion provides information about the actual location of roots

C. Cannot be used to test the stability of a control system containing transportation lag

D. Cannot determine as to how many roots of the characteristics equation have positive real roots

65. Which of the following is not a variable area flow meter ?
comments icon0

A. Orifice and tapered plug meter

B. Piston type meter

C. Magnetic flow meter

D. Rotameter

67. The closed loop pole of a stable second order system could be_______________?
comments icon0
A. Both real and positive

B. Complex conjugate with positive real parts

C. Both real and negative

D. One real positive and the other real negative

68. The response of two tanks of same size and resistance in series is __________________?
comments icon0

A. Over damped

B. Under damped

C. Critically damped

D. None of the above

69. Pirani gauge is used for the measurement of________________?
comments icon0

A. Very high pressure

B. Liquid level at atmospheric pressure

C. Liquid level under pressure

D. High vacuum
71. A stable system is the one___________________?
comments icon0

A. Which satisfies the conditions for a servo problem

B. For which the output response is bounded for all bounded input

C. None of these

D. Which exhibits an unbounded response to a bounded input

72. High temperature of around 2000C of incandescent gas mantles is measured by a/an __________________?
comments icon0

A. Specially designed thermocouple

B. Optical pyrometer

C. Radiation pyrometer

D. None of these

74. Which of the following thermocouples has the widest temperature measurement range ?
comments icon0

A. Chromel-alumel

B. Copper-constantan

C. Iron-constantan

D. Platinum-platinum/rhodium
76. Polarograph is meant for the analysis of __________________?
comments icon0

A. Miscible liquids

B. Isotopes

C. Gaseous mixture

D. Solids
78. Presence of a small amount of water in the organic systems can be determined by the _____________ method?
comments icon0

A. Polarimetry

B. Dielectric constant end loss factor

C. Electrical conductivity

D. Emission spectroscopy

79. Magnetic flowmeters are generally not used for the velocity/flow measurement of hydrocarbons due to their ?
comments icon0

A. Low thermal conductivity

B. High viscosity index

C. Low flash point

D. Low electrical conductivity
80. In second order underdamped system ?
comments icon0

A. Decay ratio = overshoot

B. Decay ratio = (overshoot)2

C. Large damping co-efficient means smaller damping

D. Overshoot increases for increasing damping co-efficient

81. Which is the most suitable instrument for measuring pressure below 3 microns ?
comments icon0

A. Mcleod gauge

B. Alphatron

C. Bourdon gauge

D. Ionisation gauge
82. Which of the following thermocouples can measure the maximum temperature ?
comments icon0

A. Chromel-alumel

B. Platinum-rhodium

C. Tungsten-molybdenum

D. Iron-constantan

83. Polarisation of light forms the working principle of a______________?
comments icon0
A. Polarimeter

B. Spectrometer

C. Chromatograph

D. Polarograph

84. Which of the following filled system expansion thermometer has the capability to measure the lowest temperature ?
comments icon0

A. Mercury in steel thermometer

B. Mercury in glass thermometer

C. Alcohol in glass thermometer

D. Fused metal (Na or K) in steel thermometer

89. Flow rate through an orifice is _____________ the pressure differential?
comments icon0
A. Proportional to the square root of

B. Proportional to

C. Inversely proportional to the square root of

D. Inversely proportional to the square of

93. ____________ are analysed using a Polarograph?
comments icon0
A. Solids

B. Gases

C. Liquids

D. Isotonic solutions

94. Which of the following is a contact pyrometer ?
comments icon0

A. Optical pyrometer

B. Infra red pyrometer

C. Resistance pyrometer

D. Radiation pyrometer

95. Which of the following thermometers is not suitable for distant reading upto 60 metres ?
comments icon0
A. Mercury in glass thermometer

B. Constant volume gas thermometer

C. Vapor pressure thermometer

D. Resistance thermometer

96. The amplitude ratio for the sinusoidal response of a _____________ is 1?
comments icon0

A. Second order system

B. None of these

C. First order system

D. Transportation lag
98. Which of the following flow-metering instruments is an areameter ?
comments icon0

A. Venturimeter

B. Rotameter

C. Hot wire anemometer

D. Pitot tube

100. Pick out the most suitable instrument for measuring temperature in the range of-40 to 425C ?
comments icon0

A. Mercury thermometer

B. Bimetallic thermometer

C. None of these

D. Radiation pyrometer