measurement and instrumentation MCQs – Page 5

Practise focused measurement and instrumentation questions with marked answers for exam preparation and subject revision.

measurement and instrumentation Mcqs
81. Which of the following essential features is possessed by an indicating instrument?
comments icon0
A. All of the above

B. Controlling device

C. Deflecting device

D. Damping device

82. E.m.f. of a Weston cell is accurately measured by________________?
comments icon0
A. electrostatic voltmeter

B. isothermal voltmeter

C. hot wire voltmeter

D. electrodynamic voltmeter

83. Standard resistor is made from_________________?
comments icon0

A. nichrome

B. maganin

C. silver

D. platinum

84. For measurement of inductance having high value, we should use______________?
comments icon0

A. Maxwells bridge

B. Any of the above

C. Maxwell Wein bridge

D. Hays bridge
85. Which of the following meters are not used on D.C. circuits______________?
comments icon0

A. Commutator motor meters

B. Mercury motor meters

C. Induction meters

D. None of the above

86. In order to achieve high accuracy, the slide wire of a potentiometer should be_______________?
comments icon0

A. neither too small not too large

B. very thick

C. as long as possible

D. as short as possible

87. Volt box is a component to_____________?
comments icon0

A. none of the above

B. compare voltage in a box

C. extend voltage range

D. measure voltage

88. Which of the following is measured by using a vector voltmeter ?
comments icon0
A. All of the above

B. Amplifier gain and phase shift

C. Complex insersion loss

D. Filler transfer functions

91. The spring material used in a spring control device should have the following property?
comments icon0

A. Most be of low temperature co-efficient

B. Should not be subjected to fatigue

C. All of the above

D. Should be non-magnetic

E. Should have low specific resistance

92. Which of the following are integrating instruments ?
comments icon0

A. Voltmeters

B. Ammeters

C. Wattmeters

D. Ampere-hour and watt-hour meters
93. Alternating current is measured by_______________?
comments icon0

A. permanent magnet type ammeter

B. moving iron repulsion type voltmeter

C. electrostatic ammeter

D. induction ammeter
94. Wagner earthing device is used to eliminate errors due to________________?
comments icon0
A. electrostatic coupling

B. electromagnetic coupling

C. both A. and B.

D. none of the above

97. A voltage of about 200 V can be measured__________________?
comments icon0
A. a D.C. potentiometer in conjunction with a volt ratio box

B. directly by a D.C. potentiometer

C. a D.C. potentiometer in conjunction with a known resistance

D. none of the above

98. For measuring a very high resistance we should use_______________?
comments icon0

A. Wheat stone bridge

B. Meggar

C. Kelvins double bridge

D. None of the above

99. The switch board instruments________________?
comments icon0

A. either A. or B.

B. should be mounted in vertical position

C. neither A. nor B.

D. should be mounted in horizontal position

100. A potentiometer may be used for_________________?
comments icon0

A. measurement of resistance

B. measurement of current

C. calibration of voltmeter

D. calibration of ammeter

E. all of the above