22. In the cables, sheaths are used to___________?
comments icon0

A. provide enough strength

B. none of the above

C. prevent the moisture from entering the cable

D. provide proper insulation

23. PVC stands for____________?
comments icon0

A. positive voltage conductor

B. pressed and varnished cloth

C. post varnish conductor

D. polyvinyl chloride

E. none of the above

24. The advantage of oil filled cables is_________?
comments icon0

A. more perfect impregnation

B. smaller overall size

C. all of the above

D. no ionisation, oxidation and formation of voids

25. Conduit pipes are normally used to protect _______ cables
comments icon0

A. PVC sheathed cables

B. all of the above

C. unsheathed cables

D. armoured

27. The material for armouring on cable is usually__________?
comments icon0
A. any of the above

B. none of the above

C. galvanised steel wire

D. steel tape

29. The surge resistance of cable is__________?
comments icon0

A. 100 ohms

B. 50 ohms

C. 5 ohms

D. 20 ohms

30. A cable carrying alternating current has__________?
comments icon0

A. hysteresis, leakage, copper and friction losses

B. hysteresis losses only

C. hysteresis and leakage losses only

D. hysteresis, leakage and copper losses only

32. The breakdown of insulation of the cable can be avoided economically by the use of___________?
comments icon0

A. inter-sheaths

B. insulating materials with different dielectric constants

C. both (A) and (B)

D. none of the above

33. The minimum dielectric stress in a cable is at_____________?
comments icon0

A. conductor surface

B. bedding

C. lead sheath

D. armour

34. Solid type cables are considered unreliable beyond 66 kV because___________?
comments icon0

A. skin effect dominates on the conductor

B. there is a danger of breakdown of insulation due to the presence of voids

C. of corona loss between conductor and sheath material

D. insulation may melt due to higher temperature

35. The thickness of metallic shielding on cables is usually_______________?
comments icon0
A. 0.04 mm

B. 3 to 5 mm

C. 40 to 60 mm

D. 0.2 to 0.4 mm

36. Is a cable is to be designed for use on 1000 kV, which insulation would you prefer ____________?
comments icon0
A. Compressed SFe gas

B. Polyvinyle chloride

C. Impregnated paper

D. none of the above

E. Vulcanised rubber

37. The current carrying capacity of cables in D.C. is more than that in A.C. mainly due to__________?
comments icon0

A. absence of harmonics

B. none of the above

C. non-existence of any stability limit

D. absence of ripples

E. smaller dielectric loss
40. Cables for 220 kV lines are invariably____________?
comments icon0

A. none of the above

B. rubber insulated

C. compressed oil or compressed gas insulated

D. mica insulated

E. paper insulated