environmental engineering MCQs – Page 4

Practise focused environmental engineering questions with marked answers for exam preparation and subject revision.

environmental engineering Mcqs
61. The characteristics of fresh and septic sewage respectively are____________________?
comments icon0

A. acidic and alkaline

B. alkaline and acidic

C. both acidic

D. both alkaline

62. Standard BOD is measured at________________?
comments icon0
A. 20C 5day

B. 25C- 3day

C. 20C 1day

D. 30C- 5day

63. The time of concentration is defined as_______________?
comments icon0
A. sum of (A) and (B)

B. the time taken by rainfall water to run from most distant point of water shed to the inlet of sewer

C. the time required for flow of water in sewer to the point under consideration

D. difference of (A) and (B)

64. Sewerage system is usually designed for_________________?
comments icon0

A. 10 years

B. 25 years

C. 75 years

D. 50 years

65. Activated carbon is used for_____________?
comments icon0
A. removing odours

B. removing corrosiveness

C. removing hardness

D. disinfection

66. The specific gravity of sewage is_______________?
comments icon0

A. slightly less than 1

B. much greater than 1

C. equal to 1

D. slightly greater than 1
67. In facultative stabilization pond, the sewage is treated by________________?
comments icon0

A. aerobic bacteria only

B. sedimentation

C. algae only

D. dual action of aerobic bacteria and anaerobic bacteria
68. The effective size of sand particles used in slow sand filters is_______________?
comments icon0

A. 0.35 to 0.60 mm

B. 1.00 to 1.80 mm

C. 0.25 to 0.35 mm

D. 0.60 to 1.00 mm

71. The suitable layout of a distribution system for irregularly growing town is_______________?
comments icon0

A. grid iron system

B. ring system

C. radial system

D. dead end system
72. The per capital consumption of a locality is affected by_________________?
comments icon0

A. quality of water

B. climatic conditions

C. distribution pressure</strong>

D. correct answer is?

73. In lime-soda process________________?
comments icon0

A. only carbonate hardness is removed

B. lime reduces the non-carbonate hard-ness and soda-ash removes the carbonate hardness

C. lime reduces the carbonate hardness and soda-ash removes the non-carbonate hardness

D. only non-carbonate hardness is re-moved

74. The maximum permissible limit for flouride in drinking water is______________?
comments icon0

A. 5 mg/litre

B. 1.5 mg/litre

C. 0.1 mg/litre

D. 10 mg/litre

77. Which of the following methods of analysis of water distribution system is most suitable for long and narrow pipe system ?
comments icon0

A. circle method

B. Hardy cross method

C. equivalent pipe method

D. electrical analysis method

79. The alum, when added as a coagulant in water_______________?
comments icon0
A. decreases pH value of water

B. does not affect pH value of water

C. increases pH value of water

D. does not require alkalinity in water for flocculation

80. The water carriage system of collection of waste product________________?
comments icon0

A. is cheaper in initial cost than dry conservancy system

B. requires treatment before disposal

C. all of the above

D. creates hygenic problem